Hỗ trợ trực tuyến
My status
Hỗ trợ kỹ thuật
My status
Hỗ trợ kinh doanh
Hotline:
098.161.1919
098.6219.626
091.5596.535
Email:
info@banhay.com
Quảng Cáo
Home > Thiết bị chống sét - Tiếp địa > Chống sét lan truyền LPI > Tủ cắt sét LPI > LPI 3PPMSG135kA-NE

LPI 3PPMSG135kA-NE

LPI 3PPMSG135kA-NE, 3PPMSG135kA-NE, LPI 3PPMSG135kA - NE, LPI-3PPMSG135kA-NE, LPI 3PPMSG-135kA-NE, 3PPMSG-135kA-NE, LPI 3PPMSG - 135kA - NE, LPI-3PPMSG-135kA-NE, tủ cắt lọc sét 3 pha, dòng sét 135kA, không phụ thuộc dòng tải, lắp song song với CB, chưa có bộ đếm, Thiết bị cắt sét 3 pha, mạch song song, có khe hở phóng điện, 50kA 10/350μs, 135kA 8/20μs Ph-N, 100kA10/350μs N-E, có màn hình hiển thị trạng thái và công tắc báo động, công ty nhập khẩu tủ cắt lọc sét 3PPMSG135kA-NE, 36 TD PPM 135KA

LPI 3PPMSG135kA-NE

LPI 3PPMSG135kA-NE, 3PPMSG135kA-NE, LPI 3PPMSG135kA - NELPI-3PPMSG135kA-NELPI 3PPMSG-135kA-NE, 3PPMSG-135kA-NE, LPI 3PPMSG -135kA - NELPI-3PPMSG-135kA-NE, tủ cắt lọc sét 3 pha, dòng sét 135kA, không phụ thuộc dòng tải, lắp song song với CB, chưa có bộ đếm, Thiết bị cắt sét 3 pha, mạch song song, có khe hở phóng điện, 50kA 10/350μs, 135kA 8/20μs Ph-N, 100kA10/350μs N-E, có màn hình hiển thị trạng thái và công tắc báo động, công ty nhập khẩu tủ cắt lọc sét 3PPMSG135kA-NE36 TD PPM 135KA

Xuất xứ: Úc

Hãng: LPI

Downloads: 

Tài liệu thiết bị chống sét LPI 3PPMSG135kA-NE: View / Download

Tài liệu tổng 1: View / Download

Tài liệu tổng 2: View / Download

LPI® Spark Gap Power Protection Module in Enclosure

Features
·  High performance surge protector for an operating voltage of 220 - 277Vac
·  Nominal impulse discharge current Ph-N 50kA 10/350μs, 135kA 8/20μs / Single Mode
·  Shunt protection in a metal enclosure

Product Description
The LPI Power Protection Module is a power line shunt surge protection device housed in a metal enclosure. The LPI Power Protection Modules comes in 2 ranges: 1 Phase and 3 Phase. Each has Class I surge protection rated for 50kA 10/350μs, 135kA 8/20μs between P-N, and 100kA 10/350μs, 150kA 8/20μs between N-E. The unit is designed for mounting at main power switchboards and distribution boards in LP Zones 0 and 1 location as per IEC 62340. The unit is supplied with IEC 61643 Class I Spark Gap Surge Diverters which provide the most effective surge protection with low let through voltage.

Ordering Code

LPI 1PPMSG135kA-NE

LPI 3PPMSG135kA-NE

Description:

Power Protection Module, Shunt , 135kA 8/20μs P-N, 100kA 10/350μs , N-E

Power Protection Module, Shunt , 3 x 135kA 8/20μs P-N, 100kA 10/350μs , N-E

Power distribution systems:

TT, TN-S, TN-C, TN-C-S (MEN)

Dimensions/ Weight:

 

300 (H) x 200 (W) x 150 (D) mm Approx.

5Kg

300 (H) x 200 (W) x 150 (D) mm Approx.

5kg

Environmental rating / Enclosure/ Mounting:

IP 55 / Metal enclosure/ Wall mount type

Conductor size / Colour:

Accepts: 35mm²

Operating temperatures:

-35 to +55°C, 0 – 95% humidity

Response time:

< 100ns

Standards:

IEC 61643 Class I

Surge withstand:

 

ANSI C62.41 Cat A, Cat B, Cat C, IEC61643

AS/NZS 1768 Cat A, Cat B, Cat C

Application:

Main and sub-distribution boards

Warranty:

5 Years

Ph-N Protection

Surge rating: Imax

135kA 8/20μs

3 x 135kA 8/20μs

Nominal Operating Voltage: Un

220 – 277Vac @ 50/60Hz

220 – 277Vac @ 50/60Hz

Let through voltage: Up

< 1.3kV @ 50kA 8/20μs

< 1.3kV @ 50kA 8/20μs

Energy capability per phase: W/R

>600kJ

>600kJ

Follow Current Interrupt rating: Ifl

25kA @ 255Vrms 50/60Hz

25kA @ 255Vrms 50/60Hz

Max Backup Fuse:

315A gL/gG

315A gL/gG

Max Continuous Operating Voltage: Uc

480Vrms

480Vrms

N-E Protection

Surge rating: Imax

150kA 8/20μs

150kA 8/20μs

Surge rating: Iimp

100kA 10/350μs

100kA 10/350μs

Insulation resistance (Risol):

>1000MΩ

>1000MΩ

 